MX-5 Miata LS L4-1.8L DOHC (2001)
Oxygen Sensor: Component Tests and General Diagnostics
Heated Oxygen Sensor (HO2S)
Inspection of Voltage
NOTE: Perform the following test only when directed.
1. Warm up the engine and run it at idle.
2. Disconnect the HO2S connector.
3. Connect a voltmeter between the HO2S connector terminal A and a GND.
4. Run the engine at 3,000 rpm until the voltmeter indicates 0 - 1.0 V.
5. Verify the voltage when engine speed is suddenly increased and decreased several times.
-
If HO2S is okay, but PID value is out of specification, perform the "Circuit Open/Short Inspection."
-
If not as specified, replace the HO2S.
6. Reconnect the HO2S connector.
Circuit Open/Short Inspection
Open circuit
-
If there is no continuity, the circuit is open. Repair or replace the harness.
-
Heated oxygen circuit (HO2S connector terminal A and PCM connector terminal 4W (Front).)
-
GND circuit (HO2S connector terminal B and PCM connector terminal 4O through common connector (Front).)
-
Heated oxygen circuit (HO2S connector terminal A and PCM connector terminal 4AA (Rear).)
-
GND circuit (HO2S connector terminal B and PCM connector terminal 4O through common connector (Rear).)
Short circuit