mazda Workshop Repair Guides

Mazda Workshop Service and Repair Manuals

Component Tests and General Diagnostics|Page 1670 > < Engine Controls - O2 Sensor Removal Precautions|Page 1667
Page 1
background image

Oxygen Sensor: Component Tests and General Diagnostics

Heated Oxygen Sensor (HO2S)

Inspection of Voltage

NOTE:  Perform the following test only when directed.

1. Warm up the engine and run it at idle.
2. Disconnect the HO2S connector.
3. Connect a voltmeter between the HO2S connector terminal A and a GND.
4. Run the engine at 3,000 rpm until the voltmeter indicates 0 - 1.0 V.

5. Verify the voltage when engine speed is suddenly increased and decreased several times.

-

If HO2S is okay, but PID value is out of specification, perform the "Circuit Open/Short Inspection."

-

If not as specified, replace the HO2S.

6. Reconnect the HO2S connector.

Circuit Open/Short Inspection 

Open circuit

-

If there is no continuity, the circuit is open. Repair or replace the harness.
-

Heated oxygen circuit (HO2S connector terminal A and PCM connector terminal 4W (Front).)

-

GND circuit (HO2S connector terminal B and PCM connector terminal 4O through common connector (Front).)

-

Heated oxygen circuit (HO2S connector terminal A and PCM connector terminal 4AA (Rear).)

-

GND circuit (HO2S connector terminal B and PCM connector terminal 4O through common connector (Rear).)

Short circuit

Component Tests and General Diagnostics|Page 1670 > < Engine Controls - O2 Sensor Removal Precautions|Page 1667