If there is continuity, the circuit is shorted. Repair or replace the harness.
-

HO2S connector terminal A and PCM connector terminal 4W to GND (Front). 

-

HO2S connector terminal A and PCM connector terminal 4AA to GND (Rear).

Heated Oxygen Sensor (HO2S) Heater

Inspection of Resistance

NOTE:  Perform the following test only when directed.

1. Disconnect the HO2S connector.
2. Measure the resistance between HO2S terminals C and D using an ohmmeter.

-

If not as specified, replace the HO2S.

-

If HO2S heater is okay, but PID value is out of specification, perform the "Circuit Open/Short Inspection".

Specification: Approx. 15.7 Ohms

3. Reconnect the HO2S connector.

Circuit Open/Short Inspection

 
Open circuit

-

If there is no continuity, the circuit is open. Repair or replace the harness.
-

GND circuit (HO2S connector D and PCM connector terminal 3J through common connector (Front).)

-

Power circuit (HO2S connector terminal C and ignition switch (IG1) circuit through common connector (Front).)

-

GND circuit (HO2S connector terminal D and PCM connector terminal 3P (Rear).)

-

Power circuit (HO2S connector terminal C and ignition switch (IG1) circuit through common connector (Rear).)

Short circuit

-

If there is continuity, the circuit is shorted. Repair or replace the harness.
-

HO2S connector terminal C and ignition switch (IG1) through common connector to GND (Front).

-

HO2S connector terminal D and PCM connector terminal 3J through common connector to GND (Front).

-

HO2S connector terminal D and PCM connector terminal 3P to GND (Rear).

Component Tests and General Diagnostics|Page 1671 > < Component Tests and General Diagnostics