MX-6 LS V6-2.5L DOHC (1997)
Starter Motor: Testing and Inspection
On Vehicle Inspection
Inspection (on vehicle)
1. Measure the battery positive voltage.
Specification: Above 12.4 V
2. Crank the engine and verify that the starter turns smoothly.
3. If the starter does not turn, check the voltage at terminal
4. If the voltage is more than 8 V, remove and inspect the starter. If the voltage is less than 8 V, check the wiring harness, ignition switch, starter
interlock switch [MTX], and transaxle range switch [ATX].