Evaporator temperature

Fresh air/air recirculation flaps actuator motor

The fresh air/recirculated air flap actuator motor facilitates the closing or opening of the fresh air supply by actuating the fresh air/recirculated air flaps.
The fresh and air recirculation flaps actuator motor is actuated by pressing the air recirculation switch (N22s2) on the AAC control and operating unit.

In air recirculation mode, the recirculation flap is open and the fresh air flap is closed. Air is drawn out of the vehicle interior into the A/C housing by the
blower.
In fresh air mode, the fresh air flap is open and the recirculated air flap is closed. Fresh air is drawn into the automatic air conditioning housing by the
blower.

When the air recirculation switch is actuated manually, the system immediately switches to 100 % recirculated air for a limited time. This is displayed by
the function LED. Time limit function:

^

after 30 min at outdoor temperatures above approx. 7 °C,

^

after 5 min at outside temperatures below approx. 7 °C,

^

after 5 min following AC OFF.

100 % automatic recirculated air is possible for 30 min after switching ON the ignition. After expiration of this time, the system goes to a 80 %
recirculated air or fresh air, depending on the conditions.
If automatic recirculated air is required after engine ON, fresh air will be circulated initially for 30 seconds. Then, operation is first continued
automatically with 80 % recirculated air and 10 s later, also with 100 % automatically recirculated air, depending on the requirement.

Tunnel function
Activation of the tunnel function:

Only possible where the recirculated air LED is not illuminated.

Actuation of the air recirculation switch for longer than 1.5 s Reaction: fresh air and air recirculation flaps are driven into air recirculation position. Now
the 4 windows and the tilting/sliding roof are closed in a staggered manner.

If the recirculated air LED is canceled manually or by the automatic timer, the fresh air and air recirculation flap goes to the fresh air position, however,
the windows and sliding roof remain closed.

Deactivation of tunnel function:

Only possible where the recirculated air LED is illuminated. Actuation of the air recirculation switch for longer than 1.5 s Reaction: Fresh air and air
recirculation flaps are driven into fresh air position. Now the 4 windows and the tilting/sliding roof are opened in a staggered manner.
If the recirculated air LED is reset manually (actuation of air recirculation switch for less than 1.5 s), the fresh air and air recirculation flap is moved to
the recirculated air position.

Special functions of the fresh air/air recirculation control:

^

The function AC OFF does not allow any automatic nor emissions-controlled recirculated air.

^

Only fresh air mode is possible in the defrosting function.

^

In the function "0" 100 % recirculated air applies.

^

Manual recirculated air is deleted after ignition OFF.

^

Manual or automatic recirculated air is possible in the "Rest" position.