mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

GF83.10-P-2201GZ Actuator Motors, Component Description|Page 10032 > < GF83.10-P-2201GZ Actuator Motors, Component Description|Page 10030
Page 1
background image

Air Door Actuator / Motor: Description and Operation
GF83.10-P-2201GZK Actuator Motor, Component Description

GF83.10-P-2201GZK Actuator Motor, Component Description

- with CODE (581) Comfort automatic air conditioning
- except CODE (582) Rear air conditioning

Component Identification

Location

The actuator motors are located on the A/C housing and are located at the respective positions as shown in the picture above.

Task

General information on actuator motors and flap control Continuous positioning of the flaps.
To prevent the actuator motors from continuously running in the controlled range, the following release function is implemented for each flap in the
automatic air conditioning.
Release function: Once a position has been adjusted, then until the next change, the specified temperature of the blown in air for example must change by
so much that the release value going above or below it is either not reached or exceeded.
Final values are approached directly (0 %, 100 %).

Anti-fogging function

The anti-fogging function prevents the windshield and side windows from fogging up after starting the engine thanks to the fact that moist air is not
guided directly against the windows after starting, but instead into the footwell of the vehicle.

Left center air flap actuator motor and right center air flap actuator motor

The left center air flap actuator motor and the right center air flap actuator motor operate the particular air flap that controls the air flow to the center
nozzles separately for left and right.
Depending upon the desired air outlet temperature at the center nozzle, the left center air flap actuator motor and the right center air flap actuator motor
are actuated via the comfort AAC [KLA] control and operating unit (N22/7).
Actuation during "Defrosting"

Center outlet flaps 0 % (closed)

Actuation during "Rest"

According to regulation

Actuation during "0"

Retain current position

Actuation during ignition OFF

Retain current position

Automatic air flap control

Depending upon the following variables, the air flaps can be opened up to 100 % by the left center air flap actuator motor and the right center air flap
actuator motor in line with a defined characteristic:

^

Blending air flap setting

^

Coolant temperature

GF83.10-P-2201GZ Actuator Motors, Component Description|Page 10032 > < GF83.10-P-2201GZ Actuator Motors, Component Description|Page 10030