mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2715 > < Initial Inspection and Diagnostic Overview|Page 2713
Page 32
background image

No

REPAIR the circuit. CONNECT the negative battery cable. CLEAR the DTCs. REPEAT the network test with the scan tool.

-------------------------------------------------
L3 CHECK THE MS-CAN CIRCUITS BETWEEN THE HVAC MODULE AND THE DLC FOR AN OPEN

-

Measure the resistance between the HVAC module C2356a-25 or C2357a-25, circuit VDB06 (GY/OG), harness side and the Data Link Connector
(DLC) C251-3, circuit VDB06 (GY/OG), harness side.

-

Measure the resistance between the HVAC module C2356a-26 or C2357a-26, circuit VDB07 (VT/OG), harness side and the DLC C251-11,
circuit VDB07 (VT/OG), harness side.

-

Are the resistances less than 5 ohms?

Yes

CONNECT the negative battery cable. GO to L4. 

No

REPAIR the circuit in question. CONNECT the negative battery cable. CLEAR the DTCs. REPEAT the network test with the scan tool.

-------------------------------------------------
L4 CHECK FOR CORRECT HVAC MODULE OPERATION

-

Disconnect all the HVAC module connectors.

-

Check for:
-

corrosion

-

damaged pins

-

pushed-out pins

-

Connect all the HVAC module connectors and make sure they seat correctly.

-

Operate the system and verify the concern is still present.

-

Is the concern still present?

Yes

INSTALL a new HVAC module. CLEAR the DTCs. REPEAT the network test with the scan tool. 

No

The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.

-------------------------------------------------

Pinpoint Test M: The Global Positioning System Module (GPSM) Does Not Respond To The Scan
Tool

Initial Inspection and Diagnostic Overview|Page 2715 > < Initial Inspection and Diagnostic Overview|Page 2713