mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Compressor Manifold and Tube Assembly|Page 1221 > < Compressor Manifold and Tube Assembly|Page 1219
Page 2
background image

-

To install, tighten to 15 Nm (133 lb-in).

4. Disconnect the low-charge protection switch electrical connector.

5. Remove the Thermostatic Expansion Valve (TXV) fitting nut and disconnect the fitting.

-

Discard the gasket seals.

-

To install, tighten to 15 Nm (133 lb-in).

6. Remove the passenger zone valve nut.

-

To install, tighten to 7 Nm (62 lb-in).

7. Remove the auxiliary evaporator inlet line fitting nut and disconnect the fitting.

-

Discard the O-ring seal.

-

To install, tighten to 8 Nm (71 lb-in).

8. Remove the receiver/drier outlet fitting nut and disconnect the fitting.

-

Discard the O-ring seal and gasket seal.

-

To install, tighten to 15 Nm (133 lb-in).

9. Disconnect the passenger zone valve electrical connector.

10. Detach the evaporator inlet line from the A/C line bracket.

11. Remove the evaporator inlet line.

12. To install, reverse the removal procedure.

-

Install new gasket seals and O-ring seals.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil.

13. Evacuate, leak test and charge the refrigerant system.

Compressor Manifold and Tube Assembly|Page 1221 > < Compressor Manifold and Tube Assembly|Page 1219