This pinpoint test is intended to diagnose the following:

-

Fuse

-

Wiring, terminals or connectors

-

HVAC module

 

PINPOINT TEST V: THE HVAC MODULE DOES NOT RESPOND TO THE SCAN TOOL

NOTICE:  Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the
connector.

NOTE:  Failure to disconnect the battery when instructed will result in false resistance readings. Refer to Battery.

-------------------------------------------------
V1 CHECK THE HVAC VOLTAGE SUPPLY CIRCUITS FOR AN OPEN

 

-

Ignition OFF.

-

Disconnect: HVAC Module C2357a (Manual A/C) .

-

Disconnect: HVAC Module C2356a (Dual Automatic Temperature Control (DATC)) .

-

Ignition ON.

-

Measure the voltage between the HVAC module C2357a-13 (manual), C228a-13 or

C2356a-13 (DATC), circuit SBP15 (WH/RD), harness side and ground.

-

Is the voltage greater than 10 volts?

Yes

GO to V2. 

No

VERIFY Smart Junction Box (SJB) fuse 15 (10A) is OK. If OK, REPAIR the circuit in question. CLEAR the DTCs. REPEAT the network test with the
scan tool. If not OK, REFER to the Wiring Diagrams to identify the possible causes of the circuit short  See: Diagrams/Electrical Diagrams/Diagrams By
Number.

-------------------------------------------------
V2 CHECK THE HVAC GROUND CIRCUIT FOR AN OPEN

 

-

Ignition OFF.

-

Disconnect: Negative Battery Cable .

-

Measure the resistance between the HVAC module C2357a-23 (manual), C228a-23 or

C2356a-23 (DATC), circuit GD116 (BK/VT), harness side and ground.

Initial Inspection and Diagnostic Overview|Page 3194 > < Initial Inspection and Diagnostic Overview|Page 3192