mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Suction Accumulator|Page 7246 > < Suction Accumulator
Page 2
background image

6. Remove the PCM bracket bolt.

7. Remove the PCM bracket nut and the PCM bracket.
8. Remove the suction accumulator stud.

-

To install, tighten to 11 Nm (8 lb-ft).

4.6L vehicles

9. Remove the suction accumulator-to-compressor line bracket nut at the condenser-to-evaporator line bracket.

All vehicles

10. Remove the 2 suction accumulator fitting nuts and disconnect the fittings.

-

Discard the O-ring seals.

-

To install, tighten to 8 Nm (71 lb-in).

11. Remove the suction accumulator bracket bolt and suction accumulator.
12. To install, reverse the removal procedure.

-

Install new O-ring seals.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil.

13. Evacuate, leak test and charge the refrigerant system. 

Suction Accumulator|Page 7246 > < Suction Accumulator