Sable V6-3.0L VIN U (1999)
8. Remove A/C cycling switch from suction accumulator/drier.
INSTALLATION
1. Install A/C cycling switch on suction accumulator/drier.
2. Position suction accumulator/drier in A/C accumulator bracket.
3. Using new O-ring seals lubricated with clean PAG Compressor Oil Motorcraft YN-12c F7AZ-19589-DA or equivalent meeting Ford specification
WSH-M1C231-B, connect suction accumulator/drier inlet tube to A/C evaporator core outlet and A/C manifold and tube to suction
accumulator/drier.
4. Tighten screw in A/C accumulator bracket.
5. Connect wire harness connector to A/C cycling switch.
6. Install A/C hose support bracket and retaining nut.
7. Install radiator coolant recovery reservoir and engine ground strap with bolt and nut.
8. Connect hoses to radiator coolant recovery reservoir.
9. Leak-test, evacuate and charge the system. Observe all safety precautions.
10. Check system for proper operation.