Pin housing:
Unlock locking slide (1) of pin housing (2) with suitable tool (3) in direction of arrow.

Insert special tool 61 1 200 into pin housing (1) and pull out lead with LCC contact (2) in direction of arrow.

Socket Housing (Radio Plug), Hybrid System MQS/MPQ

Socket Housing (Radio Plug), Hybrid System MQS/MPQ

Manufactured by AMP:

The following contact types without strand sealing can be fitted in the plug housings:

-

MQS (Micro Quadlock System)

-

MPQ, width 2.8 mm (Micro Power Quadlock)

-

MPQ, width 5.2 mm (Micro Power Quadlock)

Removing MPQ contacts from radio plug:

Press lock (1) in direction of arrow.
Detach secondary lock (2) from radio plug.