mini Workshop Repair Guides

Mini Workshop Service and Repair Manuals

Electrical - Perform Dead Battery Energy Diagnosis|Page 821 > < Electrical - Perform Dead Battery Energy Diagnosis
Page 2
background image

As an example:

Most Likely Causes listed

[1] Closed-circuit current is too high

[2] Terminal 30g-f shutdown due to start capability limit 

[3] Side Lights/Parking lights left on too long

In this example, "closed-circuit current too high" should be diagnosed and the other 2 causes should be used for informational purposes. Even though an
operating fault is listed under number [3], the most likely cause is listed as a vehicle fault.

Possible causes are:

Vehicle fault

^ Battery fault/alternator fault

^ Vehicle is not entering sleep mode

^ Vehicle is constantly woken out of sleep mode

^ Closed-circuit current is too high (only vehicles equipped with CCC Navigation SA609 and an IBS Intelligent Battery Sensor)

Operating fault

^ Lights/hazard warning lamps left on for too long

^ Terminal R/15 left on for too long

^ Unfavorable driving profile (e.g., extremely short distances)

^ Vehicle parked for too long

A functional description of Energy Diagnosis and terminal control, together with troubleshooting information, can be found in the Energy Diagnosis test
module.

2. Closed-circuit current measurement (only vehicles equipped with CCC Navigation SA609 and an IBS Intelligent Battery Sensor)

Use the following path to diagnose closed circuit current faults: Function selection\Service functions\Body\Power supply\Closed-circuit current\Evaluate
closed circuit current monitoring.

Refer to the MINI diagnosis system functional description for further information.

3. Checking the charging system

Refer to the MINI diagnosis system for testing the alternator using this following path: Function selection\Complete vehicle\Body\Power
supply\Alternator.

4. Checking the battery condition

Refer to SI M61 01 02 for battery requirements.

5. New battery registration

Registration of the new battery is necessary using the MINI diagnosis system service function. If the new battery is not registered, erroneous messages
(check control) may appear. 

Use the following path to register the new battery: Function selection\Service functions\Body\Power supply\Battery\Register battery change. Follow the
test plan instructions.

6. Recharging the battery

Refer to SI M61 03 07 for information on connecting the battery charger.

Electrical - Perform Dead Battery Energy Diagnosis|Page 821 > < Electrical - Perform Dead Battery Energy Diagnosis