mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 5488 > < Initial Inspection and Diagnostic Overview|Page 5486
Page 384
background image

1. Connect the special tool. Refer to "How to connect SWS monitor."  See: Scan Tool Testing and Procedures/How to Connect SWS Monitor
2. Turn the ignition switch to the "ON" position.
3. Operate the scan tool according to the procedure below to display "ECU COMM Check."

a. Select "Interactive Diagnosis."
b. Select "System select."
c. Select "SWS."
d. Select "SWS MONITOR."
e. Select "ECU COMM Check."

4. Scan tool (M.U.T.-III) should show "OK" on the "ECU COMM Check" menu for the "COLUMN ECU" menu.

Q: Is "OK" displayed for the "COLUMN ECU" menu?

YES : Go to Step 2.

NO : Refer to INSPECTION PROCEDURE A-2 "Communication with the column switch (column-ECU) is not possible."  See: Symptom Related
Diagnostic Procedures/Symptom Diagnostic Procedures/Inspection Procedure A-2

STEP 2. Replace the column switch.

1. Replace the column switch.
2. The input signal from the column switch (turn-signal light and lighting switch) should be able to be checked and the functions described in the

"CIRCUIT OPERATION" should work normally.

Q: Is the input signal from the column switch (turn-signal light and lighting switch) input normally?

YES : No action is necessary and testing is complete.

NO : Replace the ETACS-ECU. When the ETACS-ECU is replaced, register the encrypted code. Refer to Chassis Electrical, Encrypted Code
Registration Criteria Table. The input signal from the column switch (turn-signal light and lighting switch) should be able to be checked and the
functions described in the "CIRCUIT OPERATION" should work normally.

Initial Inspection and Diagnostic Overview|Page 5488 > < Initial Inspection and Diagnostic Overview|Page 5486