NO: Repair the wiring harness. Check that the fog lights illuminate normally.

STEP 8. Check the fog light bulb (RH).

1. Remove the fog light bulb (RH).
2. Check that the fog light bulb (RH) is not broken.

Q: Is the fog light bulb (RH) in good condition?

YES: Go to Step 9.

NO: Replace the fog light bulb (RH). Check that the fog lights illuminate normally.

STEP 9. Measure at fog light (RH) connector A-31 in order to check the ground circuit to the fog light (RH).

1. Disconnect fog light (RH) connector A-31, and measure at the wiring harness side.
2. Measure the resistance value between terminal 1 and ground.

-

The measured value should be 2 ohm or less.

Q: Does the measured resistance value correspond with this range?

YES: Go to Step 12.

NO: Go to Step 10.

STEP 10. Check fog light (RH) connector A-31 for damage.

Q: Is fog light (RH) connector A-31 in good condition?

YES: Go to Step 11.

NO: Repair or replace the connector. Refer to Harness Connector Inspection. Check that the fog lights illuminate normally.