STEP 14. Check the wiring harness between power window main switch connector E-05 and front power window sub-switch (RH) connector
E-14.

NOTE:  Also check intermediate connectors C-110 and C-17. If intermediate connectors C-110 or C-17 is damaged, repair or replace the connector as
described in Harness Connector Inspection.

Q: Is the wiring harness between power window main switch connector E-05 and front power sub-switch (RH) connector E-14 in good condition?

YES: Replace the power window main switch. When the front power window sub-switch (RH) is operated, the front power window (RH) should open
or close normally.

NO: Repair the wiring harness. When the front power window sub-switch (RH) is operated, the front power window (RH) should open or close
normally.

STEP 15. Check front power window sub-switch (RH) connector E-14 and front power window motor (RH) connector E-11 for damage.

Q: Are front power window sub-switch (RH) connector E-14 and front power window motor (RH) connector E-11 in good condition?

YES: Go to Step 16.

NO: Repair or replace the connector. Refer to Harness Connector Inspection. When the front power window sub-switch (RH) is operated, the front
power window (RH) should open or close normally.