background image

1. Turn the adjusting bolt of special tool MB991561 to adjust the opening dimension (W) to the standard value. 

NOTE:  The dimension (pig is adjusted by approximately 0.7 mm (0.03 inch) per one turn.

NOTE:  Do not turn the adjusting bolt more than one turn.

Standard value (W): 2.9 mm (0.11 inch)
When more than 2.9 mm (0.11 inch)>: Screw in the adjusting bolt.
When less than 2.9 mm (0.11 inch)>: Loosen the adjusting bolt.

CAUTION:  
^

Hold the rack housing, and use special tool MB991561 to crimp the bellows band securely.

^

Crimp the bellows band until special tool MB991561 touches the stopper.

2. Use special tool MB991561 to crimp the bellows band.

3. Check that crimped width (A) is within the standard value.

Standard value (A): 2.4 - 2.8 mm (0.09 - 0.11 inch) 
<When more than 2.8 mm (0.11 inch)>: Readjust the dimension (W) of step (1) to the value calculated by the following equation, and repeat
step (2).
W = 5.5 mm (0.22 inch) - A [Example: if (A) is 2.9 mm (0.11 inch), (W) is 2.6 mm (0.10 inch).
<When less than 2.4 mm (0.09 inch)>: Remove the bellows band, readjust the dimension (W) of step (1) to the value calculated by the
following equation, and use a new bellows band to repeat steps (2) to (3).
W = 5.5 mm (0.22 inch) - A [Example: if (A) is 2.3 mm (0.09 inch), (W) is 3.2 mm (0.13 inch).]

>>N<< TIE ROD END/TIE ROD END/JAM NUT INSTALLATION

Screw in the tie rod end to achieve the right and left length as illustrated Lock with the jam nut. 