Turn-Signal Light Power Supply Circuit Part 2

CIRCUIT OPERATION

-

The turn-signal light switch sends any signal through the column-ECU (incorporated in the column switch) to the ETACS-ECU. If the
column-ECU sends a turn-signal light switch "ON" signal to the ETACS-ECU, the ETACS-ECU turns on the flasher timer (incorporated in the
ETACS-ECU), thus causing the turn-signal lights to flash.

-

The ETACS-ECU operates the turn-signal lights according to the following signals:
-

Ignition switch (IG1)

-

Turn-signal light switch

TECHNICAL DESCRIPTION (COMMENT)

Is the turn-signal lights do not flash normally, the input circuits from the switches described in "CIRCUIT OPERATION" or the ETACS-ECU may be
defective. If the hazard warning lights do not flash, the power supply line to the ETACS-ECU (dedicated to the turn-signal lights) may be defective.

TROUBLESHOOTING HINTS

-

The column switch (turn-signal light and lighting switch) may be defective

-

The ETACS-ECU may be defective

-

The wiring harness or connectors may have loose, corroded, or damaged terminals, or terminals pushed back in the connector

DIAGNOSIS

Required Special Tools:

-

MB991223: Harness Set

-

MB991958: Scan Tool (MUT-III Sub Assembly)
-

MB991824: Vehicle Communication Interface (V.C.I.)

-

MB991827: MUT-III USB Cable

-

MB991911: MUT-III Main Harness B

-

MB991813: SWS Monitor Kit
-

MB991806: SWS Monitor Cartridge

-

MB991812: SWS Monitor Harness (For Column-ECU)

-

MB991822: Probe Harness

-

MB991854: SWS Monitor Harness (For 13-pin)

STEP 1. Verify the hazard warning light operation.

Q: Does the hazard warning light work normally?

YES: Go to Step 7.