Sentra L4-1597cc 1.6L DOHC MFI (GA16DE) (1991)
Inhibitor Switch: Testing and Inspection
Inhibitor Switch Test
1.
Disconnect connector for inhibitor switch.
2.
Using an ohm meter check for continuity as per the following.
3.
Transmission in PARK position:
Continuity between terminals A and B.
4.
Transmission in NEUTRAL position:
Continuity between terminals A and B.
Replace inhibitor switch if it fails above tests.