plymouth Workshop Repair Guides

Plymouth Workshop Service and Repair Manuals

Actuator Calibration/Diagnostics and Cool-down Test|Page 8519 > < Actuator Calibration/Diagnostics and Cool-down Test
Page 2
background image

DIAGNOSTICS

During the Actuator calibration, diagnostics are performed on the actuators and evaporator temperature Fin Sensor. 

Once diagnostics are completed the REAR WIPER and INTERMITTENT LED's will flash to indicate either a successful calibration or the
appropriate fail code(s). At this time manual testing of the Blend, Mode and Driver (if equipped) potentiometers can be performed. If a failure is
detected during Diagnostics a fault will be set in the control. When Ignition is cycled OFF and then ON or Diagnostics is aborted, the REAR
WIPER and INTERMITTENT LED's will flash simultaneously showing that a failure has occurred. The control will not indicate the fail code, but
only that a failure had occurred during the last diagnostics test. The only way to clear the failure codes is repeat the Calibration Diagnostic and
Cool-down test, after all repairs are completed.

COOL-DOWN TEST

This test has been designed for performance testing of the A/C system at the manufacturing facility. If the HVAC control module is replaced, the
Cool-down test will occur during Calibration test. During the Cool-down test the control will monitor the temperature of the Fin Sensor. The A/C
system must be able to bring the evaporator temperature down a predetermined minimum amount in less than 2 minutes.

NOTE:  Cool-down will not occur on Heater Only units.

CALIBRATION/COOL-DOWN LED DISPLAY CODES

Calibration/Cooldown Test LED's

NOTE:  See chart for definition of flashing LED's. If no problems are found, the control functions normally.

CALIBRATION/DIAGNOSTICS TEST ENTRY

TO INITIATE TESTS:

-

Set Blower motor ON HIGH

-

Set Mode position to Panel

-

Open all A/C outlets

-

Set Temperature to Cold (Both slide pots if equipped)

-

Depress WASH and REAR WIPER button simultaneously for 5 Seconds (Until all LED's light)

RESULTS:

-

All LED's will turn on for 5 Seconds

-

Calibration Test is running when REAR WIPER and INTERMITTENT are alternately flashing. Cool-down test is running if A/C and RECIRC
are alternately flashing.

-

Acceptable result is REAR WIPER LED is the only LED flashing. Push Rear Wiper to exit.

-

After all tests have passed, Calibration Diagnostics and Cool-down can be run separately.

COOL DOWN TEST ENTRY