plymouth Workshop Repair Guides

Plymouth Workshop Service and Repair Manuals

Electronic EGR Transducer (EET) Solenoid Operation|Page 5008 > < Electronic EGR Transducer (EET) Solenoid Operation|Page 5006
Page 1
background image

EGR Control Solenoid: Testing and Inspection

Circuit F18 splices to feed the ABS control module, PCM, duty cycle EVAP/Purge solenoid and the EMCC solenoid. The F18 circuit also connects to a
bus bar in the PDC that supplies voltage to the coil side of radiator fan relay, A/C clutch relay, and fuel pump relay.

In the START or RUN position, the ignition switch connects circuit A1 from the fuse block and circuit A21. Circuit A1 connects to battery voltage and
is protected by a 30 amp fuse in the PDC.