Tighten compressor bolt to 22 Nm (200 in. lbs.).

To Condenser

Fig 33  Suction And Liquid Lines

REMOVAL

1. Remove refrigerant from the A/C system using a refrigerant recovery machine.
2. Remove liquid line from condenser. 

-

Remove flange bolts attaching lines to the receiver/drier. 

-

Remove flange.

CAUTION:  Cap all lines that are not being replaced and cap the condenser inlet.

3. Disconnect liquid line from the receiver/drier.
4. Remove the liquid line from the vehicle.

INSTALLATION

For installation, reverse the above procedures.

Housing Assembly HVAC > < Handling Tubing and Fittings|Page 4556