pontiac Workshop Repair Guides

Pontiac Workshop Service and Repair Manuals

Expansion Block/Orifice Tube|Service and Repair|Page 8965 > < Expansion Block/Orifice Tube|Service and Repair
Page 2
background image

8. Inspect the expansion (orifice) tube for the following conditions and clean or replace with a new tube as indicated:

^

Broken plastic frame; replace tube

^

Filter screen (1,2) torn, damaged or plugged with fine gritty material; replace tube

^

Brass orifice tube (3) damaged or plugged; replace tube

^

Filter screen (1) coated with metal chips, flakes, or slivers; coating may be removed with low pressure shop air and reused if cleaned
satisfactorily
If reusing the tube, install a new O-ring (4)

INSTALLATION PROCEDURE

1. Lightly coat the new orifice tube O-ring seal (4) with mineral base 525 viscosity refrigerant oil.
2. Remove the cap or tape from the evaporator line.
3. Using pliers, CAREFULLY grasp the edge of the expansion (orifice) tube (long filter screen (1) inlet side of tube) without touching the filter

screen and insert the tube (short filter screen (2) outlet side first) fully into the evaporator line.

4. Remove the cap or tape from the condenser line.
5. Using a lint-free clean, dry cloth, carefully clean the sealing surfaces of the line fittings.
6. Coat the O-ring seal with mineral base 525 viscosity refrigerant oil.

Expansion Block/Orifice Tube|Service and Repair|Page 8965 > < Expansion Block/Orifice Tube|Service and Repair