pontiac Workshop Repair Guides

Pontiac Workshop Service and Repair Manuals

HVAC - Automatic|Page 13225 > < HVAC - Automatic|Page 13222
Page 1
background image

Air Door Actuator / Motor: Service and Repair
HVAC - Automatic

Air Temperature Actuator Replacement - Left

Air Temperature Actuator Replacement - Left

Removal Procedure

1. Remove the left closeout panel.
2. Disconnect the electrical connector from the left air temperature actuator.
3. Remove the mounting screws from the left air temperature actuator.

4. Remove the left air temperature actuator.

Installation Procedure

1. Position the left air temperature actuator. Align the slots in the electric actuator driver to the flats on the shaft.
2. Align the locating hole to the alignment pin on the HVAC module case.
3. Slide the actuator on the shaft. The actuator driver should seat completely onto the shaft and the mounting holes should be flush with the mounting

screws on the HVAC module case.

Notice:  Refer to Fastener Notice.

4. Install the mounting screws to the left air temperature actuator.

Tighten the screws to 1.5 N.m (13 lb in).

5. Connect the electrical connector to the left air temperature actuator.
6. Install the left closeout panel.
7. Calibrate the actuator. Refer to Re-Calibrating Actuators.  See: Testing and Inspection/Programming and Relearning

Air Temperature Actuator Replacement - Right

Air Temperature Actuator Replacement - Right

Removal Procedure

1. Remove the right side instrument panel (I/P) insulator.
2. Remove the I/P compartment.

HVAC - Automatic|Page 13225 > < HVAC - Automatic|Page 13222