Grand Prix V6-3.8L (2007)
1. Remove the right instrument panel (I/P) insulator.
2. Remove the I/P compartment.
3. Remove the screws that secure the mode actuator (1) to the HVAC module assembly.
4. Remove the mode actuator from the HVAC module assembly.
5. Disconnect the electrical connector from the mode actuator.
Installation Procedure
1. Position the mode actuator, aligning the slots in the electric actuator drive to the flats on the shaft.
2. Align the locating hole to the alignment pin on the HVAC module assembly.
3. Slide the actuator drive completely onto the shaft, with the mounting holes flush with the mounting screw holes on the HVAC module assembly.
Notice: Refer to Fastener Notice.
4. Install the screws to the mode actuator (1).
Tighten the screws to 1.5 N.m (13 lb in).
5. Connect the electrical connector to the mode actuator.
6. Install the I/P compartment.
7. Install the right I/P insulator.
8. Calibrate the actuator. Refer to Re-Calibrating Actuators. See: Testing and Inspection/Programming and Relearning
Recirculation Actuator Replacement
Recirculation Actuator Replacement