7. Install new O-rings lubricated with mineral base 525 viscosity refrigerant oil.
8. Install the evaporator inlet (4) and outlet (3) tubes to the evaporator.

9. Install the heater hoses (2, 3) to the heater core.

10. Fill the cooling system. Refer to Draining and Filling Cooling System.
11. Evacuate and Recharge the A/C system. Refer to Refrigerant Recovery and Recharging.
12. Connect the negative battery cable.

Tighten
Tighten the negative battery cable to 15 N.m (11 lb ft).

13. Operate the A/C system and test for refrigerant leaks. Refer to Leak Testing.