4. Pull carefully on the optical waveguide, e.g. -B- in the -direction of the arrow-. If it is not possible to pull out the optical waveguide, check again

whether the lock has been completely unlocked.

-

Conduct a visual check of the locks, the connector housing and the contacts for any possible damage and, if necessary, replace the damaged parts.

Installing optical contacts on bushing side

-

Remove the protective dust cap immediately before the connection procedure.

-

Check that the contact is in proper condition.

-

Given a force of 10 N, the springs installed at the connector are pressed together. This leads to an increase in the absorption, which may lead to
system impairments or even system failures. Therefore it is only permissible to pull the optical waveguide out of the connectors with a maximum
force of 10 N.

1. Push the optical contacts -B- and -A- into the module until they engage perceptibly. Check for proper seating of the optical contacts.

2. Connect the module to the connector on the bushing side.

3. Push the spring cap on to the connector until it engages perceptibly -arrow-.

Optical waveguide modules

At least one transmitter diode and one receiver diode is installed in all MOST control modules. A transmitter diode of an MOST device is connected to
the respeective receiver diode of a second MOST device. A circuit is created, in which the light signal in every control module is refreshed (the light
signal is converted to an electrical signal in every control module).