Unplug the temperature sensor connector. Check the leads by measuring the voltage on pin 1 of the connector (5v). If no voltage is present, check
pin 35 of the 39-pin connector when it is plugged into the EDU control module.

2

If no voltage is present, try another EDU that is known to be OK.

3

If voltage is present, unplug the 39-pin connector and check the lead between pin 35 and pin 1 of the sensor.

4

With the ignition switched off and the 39-pin connector unplugged, check the ground lead between pins 2 and 28 for continuity.

5

With the connector unplugged, check the resistance of the outside temperature sensor. The resistance varies with the temperature.

Minimum

Maximum 

(k/ohms)

(k/ohms)

± 0°C

5,8

6,2

+ 10°C

3,8

4,1

+ 20°C

2,5

2,8

+ 30°C

1,7

1,9

6

If the resistance is correct and the wiring intact, try another EDU control module that is known to be OK.

7

Clear the diagnostic trouble codes in the ACC unit.

Fault Symptom 2

No Fault Codes

Permanently high temperature indication (+50c),

Action

Check the resistance of the outside temperature sensor as described in point 5 on Fault Symptom 1 and check the wiring for short circuits.  See:
Diagnostic Routines/Outside Temperature Sensor/Fault Symptom 1

Fault Symptom 3

Diagnostic Trouble Code In The ACC Unit Or DCC Unit:

46391

No signals from the EDU control module to the ACC unit

F2

No signals from the EDU control module to the DCC unit

Temperature indication is normal in the EDU control module.