saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Air Bag Control Module|Diagrams|Page 243 > < Air Bag Control Module|Diagrams|Page 241
Page 1
background image

Air Bag Control Module: Service and Repair

Inflatable Restraint Sensing and Diagnostic Module Replacement

Removal Procedure

Warning:  Refer to Battery Disconnect Warning   (See: Starting and Charging/Battery/Service Precautions).

1. Disconnect the battery.
2. Wait 1 minute for the airbag to deactivate.
3. Remove the front floor console. Refer to Front Floor Console Replacement   (See: Body and Frame/Interior Moulding / Trim/Console/Service and

Repair).

4. Remove the airbag control unit.

Remove the 3 nuts (1) and remove the control unit.

5. Loosen the airbag wiring harness.

Air Bag Control Module|Diagrams|Page 243 > < Air Bag Control Module|Diagrams|Page 241