SW2 L4-1.9L DOHC VIN 7 (1997)
Parking Lock Cable: Service and Repair
Installation
1. Install the new park lock cable.
2. Route cable around HVAC module fin.
3. Route cable through accelerator pedal bracket retainer clip.
4. Install park lock cable fitting end to control base assembly. Be sure to seat fitting completely.
5. Attach park lock cable end terminal to plastic lock-out lever on the control assembly.