5. Remove the generator control module cover bolts and cover.
6. The generator control module will have to be checked for voltage potential using a voltmeter. First, verify that the voltmeter works:

1. Set the voltmeter to DC voltage.
2. Measure the vehicle's 12-volt battery voltage.
3. The meter should read greater than +12 volts DC.

7. Now, check the generator control module for voltage potential, in order to ensure that the module has been disabled.

1. Measure from the 36-volt positive terminal (3) to vehicle chassis ground (2). The voltage should be less than 3 volts.
2. Measure from the 12-volt positive terminal (5) to vehicle chassis ground (2). The voltage should be less than 3 volts.
3. Measure from the negative terminal (4) to vehicle chassis ground (2). The voltage should be less than 3 volts.

Caution:  To help avoid personal injury, always treat the 3-phase cable and connectors as if voltage is present and as if the surface of all
parts of the cable is hot.

8. Verify that the generator control module 3-phase cables are disabled.