VUE FWD L4-2.4L Hybrid (2007)
Caution: To help avoid personal injury, additional precautions must be taken prior to working on the generator control module or the
generator starter. After removing the 36V battery cables from the generator battery, remove both engine wiring harness connectors from
the generator control module. Wait at least 5 minutes and then remove the generator control module cover. Verify voltage levels at all
36V, 12V, and 3-phase connections, are less than 3 volts using a DMM before proceeding.
26. Disconnect the 2 engine wiring harness electrical connectors (1) from the generator control module.
27. WAIT at least 5 minutes in order to allow the voltage stored in the generator control module to discharge.
28. Remove the generator control module cover bolts and cover.
29. The generator control module will have to be checked for voltage potential using a voltmeter. First, verify that the voltmeter works:
1. Set the voltmeter to DC voltage.
2. Measure the vehicle's 12-volt battery voltage.
3. The meter should read greater than +12 volts DC.