saturn Workshop Repair Guides

Saturn Workshop Service and Repair Manuals

Generator Battery Control Module Cover Replacement|Page 4524 > < Generator Battery Control Module Cover Replacement|Page 4522
Page 1
background image

Drive Motor Control Module: Service and Repair
Generator Control Module Replacement

Generator Control Module Replacement

Removal Procedure

1. Disconnect the hybrid battery.
2. Remove the (12-volt) battery tray.
3. Remove the generator control module 3-phase cable bracket bolt at the tie bar.

Caution:  To help avoid personal injury, additional precautions must be taken prior to working on the generator control module or the
generator starter. After removing the 36V battery cables from the generator battery, remove both engine wiring harness connectors from
the generator control module. Wait at least 5 minutes and then remove the generator control module cover. Verify voltage levels at all
36V, 12V, and 3-phase connections, are less than 3 volts using a DMM before proceeding.