Leon Mk2
Selector lever control cable - Assembly overview |
Note
Lubricate the support points and contact surfaces with polycarbamide grease → Parts catalogue. |
1 - | Gearchange control cable |
q | Fit into the gear lever guide |
q | Installation position → Chapter |
2 - | Selection control cable |
q | Connected to the relay lever |
q | Installation position → Chapter |
3 - | Securing washer |
4 - | Securing washer |
q | Do not damage the cables when removing |
5 - | Lever protection box |
6 - | Counter support |
7 - | Elastic pin |
q | For counter support on the gearbox |
8 - | Separator |
9 - | 25 Nm hexagonal bolt |
q | For counter support |
10 - | Cable attachment |
q | For selection control cable in idler lever |
q | Always replace when the relay lever is removed |
11 - | Cable attachment |
q | To secure selection control cable to relay lever |
q | Always replace when the relay lever is removed |
12 - | Securing washer |
13 - | Bearing bush |
14 - | Return lever |
q | installation position |
15 - | Runner |
16 - | Selection pole with a counterweight |
q | Position so that the interrupted division of the teeth is adjusted to the selector rod |
q | Once fitted, adjust the gear operation mechanism → Chapter. |
q | installation position |
17 - | Hexagon nut, 25 Nm |
q | With washer |