seat Workshop Repair Guides

SEAT Workshop Service and Repair Manuals

Table of the measurement values > < Finalise emission 06
Read measurement value block 08
Read measurement value block 08
  Note!
t  While the function “read measurement value block” is working, the Autoclima is being adjusted.
t  For vehicles where Autoclima is fitted with heating and air conditioning: 6 numbers of indication groups may be selected that offer up to 4 measurement values on the display.
t  For vehicles where Autoclima is fitted only with heating: 5 numbers of indication groups may be selected that offer up to 4 measurement values on the display.
t  Should the unit -J255- have to be replaced due to a fault, when the voltage is turned off and on, this will identify the system installed. The display of the -V.A.G 1551- will show the code 220 for the Autoclima “heating and air conditioning, and 110 for the Autoclima” heating".
t  To read the measurement data during a test run, a second mechanic will be needed on board.
–  Turn on the fault reader -V.A.G 1551-, select the address code “08 electronics of the air conditioning and heating” and continue switching until the display shows “enter function XX” → Chapter.
   
Indication on the display (Function selection):
–  Press the keys 0 y 8 (08 is used to begin the function “read measurement value block”).
 
Fast Data Transmission              HELP
Select function XX                      
Indication on the display:
–  Confirm the entry with Q.
 
Fast Data Transmission                 Q
08 - Read measurement value block       
Indication on the display:
–  Enter the group number required.
 
Read measurement value block            
Enter the indication group number XXX   
Indication on the display:
–  Confirm the entry with Q.
 
Read measurement value block           Q
Enter the indication group number    001
Indication on the display:
  Note!
t  Meaning of the values of the different indication fields → Chapter.
t  If the printer is on, the indication on the display is printed on the printer paper tape.
t  Consul the fault memory once the function “read measurement value block” has finished → Anchor.
t  If the theoretical values are attained in all indication fields:
–  Press the key .
 
Read measurement value block 1         →
1            2            3            4
Indications on the display (Function selection):
  Note!
Proceed as follows to go on to another indication group:
 
Fast Data Transmission              HELP
Select function XX                      
Indication group-V.A.G 1551--V.A.G 1552-
UpperPress key 3Press key
LowerPress key 1Press key
SkipPress key CPress key C

   

Table of the measurement values > < Finalise emission 06