Condensed water drain valve (evaporator drain)
Condensed water drain valve (evaporator drain)
   
Check the valve for the condensation water outlet
Check this if the floor beneath the air conditioning gets wet with the air conditioning connected.
–  Open the perforation of the cover -1- in the lower part of the heat-proof mat -4- and open the cover upwards.
To guarantee the valve for the condensation water outlet operates correctly, make the following checks:
t  The valve for the condensation water outlet -5- must not be obstructed.
t  The sealing lip -3- of the seal in the transverse panel (mounting plate) must be placed in the support groove -2--arrows-.
t  The valve for the condensation water outlet is fixed in the support -2- and in the air conditioning unit.
t  The heat-proof mat must not be deformed or defective around the area of the valve for the condensation water outlet.
  Note
The cover -1- must close flush with the heat-proof mat -4-. If the cover is too tight -1-, it could jam the cap of the valve for the condensation water outlet -5-.
  E87-0082