O-rings for refrigerant circuit |
t
| O-rings should always only be used once and must then be renewed. |
t
| Coat O-rings with refrigerant oil before fitting. |
t
| Observe correct positioning of O-rings on pipe or in groove. |
t
| Work in a clean area (even small impurities such as a hair for example can cause leaks). |
Note t
| Only O-rings which are resistant to refrigerant R134a and the corresponding refrigerant oil may be installed. These O-rings are easily identified by their colour to avoid possible confusion (currently „red“, „purple“ or „violet“): → Spare parts catalogue. |
|
|
|