Leon Mk2
|
1 - | Compressor control valve, air conditioning -N280- |
q | Check activation and operation → Anchor1) |
2 - | Compressor: |
q | Detaching compressor from holder/re-attaching → Chapter and → Anchor1) |
q | When installing the refrigerant pipes and the corresponding holder, make sure there is sufficient distance between the belt, holder and pulley. |
q | Type of compressor differs depending on engine (attached to right or left of engine, 6-cyl. diesel or petrol engine) → Spare parts catalogue |
q | Different types of compressor are fitted depending on country version (e.g. “Denso” type designation “6 SEU” for Europe and “7 SEU” for hot countries) → Spare parts catalogue |
3 - | Pulley/compressor drive unit to engine |
q | Replace the pulley → Chapter |
q | Removing and installing poly V-belt → Anchor1) and → Engine, mechanics; Rep. Gr.13 |
q | Ribbed belt allocation: → Spare parts catalogue |
q | Checking/renewing compressor drive unit |
Note
t | A rubber element is fitted between pulley/drive unit and drive shaft of compressor to protect belt/drive gear unit in the event of compressor blockage or stiffness. |
t | The rubber section interrupts power transmission to the compressor if the compressor is sticking. |
t | A rubber element is fitted between the engine and compressor to protect the drive gear unit in the event of compressor blockage or stiffness. |
t | These rubber elements absorb any vibration occurring during compressor operation (damper function in the case of torque fluctuations). |
4 - | Oil drain bolt |
5 - | Pressure relief valve |
6 - | Junction with valve |
7 - | High-pressure sender -G65- → Anchor1) |
q | Removing and installing → Chapter |
q | Checking signal |
8 - | Condenser |
9 - | Cover cap |
q | With seal |
q | Always bolt on |
10 - | Service connection |
q | High-pressure side. |
q | For specialist air conditioner workshop for measuring, draining and filling |
11 - | Screw connection in refrigerant pipe |
12 - | Restrictor: |
q | Fitted in screw connection -item → Item- |
13 - | Evaporator |
14 - | Service connection |
q | Low-pressure side. |
q | For specialist air conditioner workshops for measurement and drainage |
15 - | Cover cap |
q | With seal |
q | Always bolt on |
16 - | Collecting tank |