Checking ambient temperature switch F38 >
< Checking overheating sensor G189
Leon Mk2
Heating, ventilation, air conditioning system
Supplementary heating
Aux. heater/heater booster
Auxiliary heater -B5W- S / -D5W- S, vehicles 06.2000??
Checking coolant temperature sender for heater G241
Checking coolant temperature sender for heaterG241
Checking coolant temperature sender for heater -G241-
Before beginning repair work, perform the following jobs:
–
Remove heater unit
→ Chapter
.
–
Remove heater control unit -J162-
→ Chapter
.
–
Pull connector housing off control unit.
–
Measure resistance between chamber 3 and chamber 4 at blue cables.
R = resistance in KΩ
t = temperature in °C
–
Please measure resistance at prevailing temperature.
Evaluation: defective > approx. 2 MΩ = open circuit; defective < 50 Ω = short circuit
Heating, ventilation, air conditioning system
Supplementary heating
Aux. heater/heater booster
Auxiliary heater -B5W- S / -D5W- S, vehicles 06.2000??
Checking coolant temperature sender for heater G241
Checking ambient temperature switch F38 >
< Checking overheating sensor G189