Auxiliary heater -B5W- S / -D5W- S, vehicles 06.2000??
Checking overheating sensor G189
Checking overheating sensorG189
Checking overheating sensor -G189-
Before beginning repair work, perform the following jobs:
–
Remove heater unit
→ Chapter
.
–
Remove heater control unit -J162-
→ Chapter
.
–
Pull connector housing off control unit.
–
Measure resistance between chamber 5 and chamber 6 at red cables.
R = resistance in KΩ
t = temperature in °C
–
Please measure resistance at prevailing temperature.
Evaluation:
t
Defective > 2M Ω = open circuit
t
Defective < 50 Ω = short circuit