seat Workshop Repair Guides

SEAT Workshop Service and Repair Manuals

Checking overheating sensor G189 > < Removing coolant temperature sender for heater G241
Checking flame monitorG64
Checking flame monitor -G64-
Before beginning repair work, perform the following jobs:
–  Remove heater unit → Chapter.
–  Remove heater control unit -J162- → Chapter.
–  Pull connector housing off control unit.
   
–  Measure resistance between chamber 2 and chamber 1 at brown and blue cable.
R = resistance in Ω
t = temperature in °C
–  Please measure resistance at prevailing temperature.
Evaluation:
t  Defective > 3040 Ω = open circuit
t  Defective < 780 Ω = short circuit
  N82-0066

Checking overheating sensor G189 > < Removing coolant temperature sender for heater G241