| Remove heat shield sleeve. |
–
| Remove the vacuum hose from the vacuum socket and connect the Manual vacuum pump -VAS 6213- in its place. |
–
| Operate hand vacuum pump to create a vacuum. |
l
| The linkage of the exhaust gas recirculation cooler changeover must move -arrows-. |
If linkage does not move or only moves in jerks: |
t
| Vacuum actuator is defective. |
t
| Changeover flap for exhaust gas recirculation is tight. |
Note When fitting the heat protection plate, fit to the same location. |
|
|
|