| Unscrew bolts -1- and remove air filter housing top section from top. |
–
| Take out old filter element. |
–
| Release retainer for bottom section of air cleaner housing (press in rubber on left and right side and pull upwards). |
To ensure the proper function of the air mass meter -G70- it is important to observe the following instructions. |
Note t
| If the air filter element is very dirty or wet, dirt or water could reach the air mass meter -G70- and affect the air mass value. This would lead to loss of power, since a smaller injection quantity is calculated. |
t
| Genuine filter cartridges must always be used for the air filter. |
t
| The hose connections and hoses for charge air system must be free of oil and grease before fitting. Do not use silicone based lubricants when installing. |
t
| The air filter housing elements must be clean. |
t
| Upon blowing the air filter housing with pressurised air take note of the following: To prevent malfunctions, cover all critical parts of the engine air intake tract such as air mass meter, intake pipes, etc. with a clean cloth. |
t
| Please observe requirements for disposal. |
|
|
|