| Connect the connecting piece -V.A.G 1274 B/1- together with the connecting hose of the device to the cooling system tester -V.A.G 1274 B- |
–
| Using hand pump on tester, build up a pressure of approx. 1.0 bar. |
DANGER! Risk of burn injuries! Before removing the cooling system tester -V.A.G 1274 B- from the connecting hose or from the connecting piece -V.A.G 1274 B/1-, the pressure must be released. For this purpose, press the pressure relief valve cooling system tester -V.A.G 1274 B- until the pressure gauge equipment displays the value »0«. |
|
–
| Locate the leak and rectify the fault. |
Testing pressure relief valve in filler cap: |
–
| Screw the cap into the adapter -V.A.G 1274/9-. |
–
| Place the connecting piece -V.A.G 1274 B/1- on the Cooling system tester adaptor -V.A.G 1274/9-. |
|
|
|