t
| Ultrasonic cleaning unit -VAS 6418-, see equivalent → Anchor |
t
| Injector-pump units placement plate -VAS 6418/3-, see equivalent → Anchor |
t
| Cleaning product Feroclean -D 600 200 A2- |
Note t
| To clean the unit injectors it is imperative to use the unit injector placement plate -VAS 6418/3-. In no way should you submerge the whole injector-pump unit in the cleaning fluid. |
t
| The injector-pump units should be placed in service the same day they were cleaned. |
t
| It is recommended to use hot water from the tap and place the unit cover to reduce the heating time of the cleaning fluid. |
t
| Replace the cleaning fluid each week and clean 5 sets of injector-pump units as a maximum for each batch of fluid. |
t
| Refill the evaporated cleaning fluid with tap water. |
t
| Do not use the fluid to clean other components. |
t
| Do not clean the outside of the injector-pump units mechanically (with a metallic brush, abrasive, etc.). |
t
| Replace the O-rings, the round head bolts and the holding and adjusting screws. |
|
|
|