skoda Workshop Repair Guides

Skoda Workshop Service and Repair Manuals

Testing resistance > < Testing the operation of the activated charcoal filter system
Check tightness
Check tightness
In dead condition the solenoid valve is closed.
–  Detach hose from activated charcoal filter solenoid valve 1 -N80-.
–  Connect a suitable manometer and a compressed air device (air pump) to the solenoid valve.
–  Generate a visible air pressure.
–  Initiate an actuator diagnosis and select the activated charcoal filter solenoid valve 1 -N80- → Chapter.
–  When the solenoid valve is opened the displayed air pressure must drop and when it is closed it must clearly rise again, if not replace the solenoid valve.
   

Testing resistance > < Testing the operation of the activated charcoal filter system