Display -V.A.G 1552 - | Possible cause of fault | Rectifying fault |
00538 Reference voltage | Signal too great
Signal too small | t
| Short circuit or open circuit on wiring or plug connections to air conditioning system control unit -J301- |
| –
| Check wiring and plug connections to the air conditioning system control unit -J301- according to the current flow diagram. |
|
|
t
| The temperature flap control motor -V68- or the fresh/re-circulating air flap control motor -V154- is defective. |
| –
| Analysing measured value block 004 and 005 → Chapter. |
–
| Performing final control diagnosis (function 03) → Chapter. |
–
| Successively remove plug connections on the temperature flap control motor -V68- and on the fresh/re-circulating air flap control motor -V154-, erase fault memory and interrogate again → Chapter. If the fault “reference voltage” is no longer detected, replace the corresponding control motor causing the fault once the connector is plugged in. |
|
t
| Air conditioning system control unit -J301- defective |
| –
| If necessary replace air conditioning system control unit -J301- → Chapter and perform “Initiate basic setting” (function 04). |
|
00576 Terminal 15 | Signal too high | t
| Voltage regulator on AC generator defective |
| |
t
| Wiring or plug connections to the air conditioning system control unit -J301- defective |
| –
| Check wiring and plug connections to the air conditioning system control unit -J301- according to the current flow diagram. |
|
Signal too low | | |
| |
t
| Wiring or plug connections to the air conditioning system control unit -J301- defective |
| –
| Check wiring and plug connections to the air conditioning system control unit -J301- according to the current flow diagram. |
|
Open circuit/short-circuit to earth | t
| Open circuit or short-circuit to earth on wiring or plug connections to air conditioning system control unit -J301- |
| –
| Check wiring and plug connections to the air conditioning system control unit -J301- according to the current flow diagram. |
|
00705 Relay for radiator fan 1st speed -J279 1) | Short circuit to positive | t
| Short-circuit to positive on wiring or plug connections to the radiator fan control unit -J293- |
| –
| Check wiring and plug connections to the radiator fan control unit -J293- according to the current flow diagram. |
|
| |
Open circuit/short-circuit to earth | t
| Open circuit or short-circuit to earth on wiring or plug connections to radiator fan control unit -J293- |
| –
| Check wiring and plug connections to the radiator fan control unit -J293- according to the current flow diagram. |
|
| |
00706 Relay for radiator fan 2nd speed -J513 1) | Short circuit to positive | t
| Short-circuit to positive on wiring or plug connections to the radiator fan control unit -J293- |
| –
| Check wiring and plug connections to the radiator fan control unit -J293- according to the current flow diagram. |
|
Open circuit/short-circuit to earth | t
| Open circuit or short-circuit to earth on wiring or plug connections to radiator fan control unit -J293- |
| –
| Check wiring and plug connections to the radiator fan control unit -J293- according to the current flow diagram. |
|
| |
00818 Evaporator vent temperature sender | Short circuit to earth | t
| Short-circuit to earth on wiring or plug connections to the evaporator vent temperature sender -G263- |
| –
| Check wiring and plug connections to the evaporator vent temperature sender -G263- according to the current flow diagram. |
|
| –
| Analysing measured value block 002 → Chapter |
|
Open circuit/short circuit to positive | t
| Open circuit or short-circuit to positive on wiring or plug connections to the evaporator vent temperature sender -G263- |
| –
| Check wiring and plug connections to the evaporator vent temperature sender -G263- according to the current flow diagram. |
|
| –
| Analysing measured value block 002 → Chapter |
|
00819 High pressure sender -G65 | Short circuit to positive | t
| Short-circuit to positive terminal or plug connections to the high pressure sender -G65- |
| –
| Check wiring and plug connections to the high pressure sender -G65- in accordance with the current flow diagram |
|
| –
| Analysing measured value block 002 → Chapter |
|
Open circuit/short-circuit to earth | t
| Open circuit or short-circuit to earth on wiring or plug connections to high pressure sender -G65- |
| –
| Check wiring and plug connections to the high pressure sender -G65- in accordance with the current flow diagram |
|
| –
| Analysing measured value block 002 → Chapter |
|
Signal too great
Signal too small | t
| Open circuit or short-circuit to earth or positive on wiring or plug connections between high pressure sender -G65- and air conditioning system control unit -J301- |
| –
| Check wiring and plug connections to the high pressure sender -G65- in accordance with the current flow diagram |
|
t
| Faults in the refrigerant circuit (positive pressure or negative pressure) |
| –
| Proceed with fault finding without self-diagnosis |
|
| |
t
| Compressor regulating valve, air conditioning system -N280- defective |
| –
| Analysing measured value block 002 → Chapter |
|
t
| Air conditioning system control unit -J301- defective |
| –
| If necessary replace the air conditioning system control unit -J301- → Chapter and perform initiate basic setting (function 04). |
|
00898 Air conditioning compressor control | Short circuit to earth | t
| Short-circuit to earth on wiring or plug connections to the compressor regulating valve, air conditioning system -N280 - |
| –
| Check wiring and plug connections to the compressor regulating valve, air conditioning system -N280- according to the current flow diagram. |
|
| –
| Analysing measured value block 002 → Chapter |
–
| Performing final control diagnosis (function 03) → Chapter |
|
t
| Air conditioning system control unit -J301- defective |
| –
| If necessary replace the air conditioning system control unit -J301- → Chapter and perform initiate basic setting (function 04). |
|
Open circuit/short circuit to positive | t
| Short-circuit to positive on wiring or plug connections to the compressor regulating valve, air conditioning system -N280- |
| –
| Check wiring and plug connections to the compressor regulating valve, air conditioning system -N280- according to the current flow diagram. |
|
| –
| Analysing measured value block 002 → Chapter |
–
| Performing final control diagnosis (function 03) → Chapter |
|
t
| Air conditioning system control unit -J301- defective |
| –
| If necessary replace the air conditioning system control unit -J301- → Chapter and perform initiate basic setting (function 04). |
|
00926 Terminal 30 | Signal too low | | |
| |
t
| Wiring or plug connections to the air conditioning system control unit -J301- defective |
| –
| Check wiring and plug connections to the air conditioning system control unit -J301- according to the current flow diagram. |
|
Signal too high | t
| Voltage regulator on AC generator defective |
| |
t
| Wiring or plug connections to the air conditioning system control unit -J301- defective |
| –
| Check wiring and plug connections to the air conditioning system control unit -J301- according to the current flow diagram. |
|
01087 Basic setting not performed | | t
| Basic setting (function 04) was not or incorrectly performed. |
| –
| Perform initiate basic setting (function 04) → Chapter |
|
01233 Coolant shut-off valve -N279 2) | Short circuit to positive | t
| Short-circuit to positive terminal on wiring or plug connections to the coolant shut-off valve -N279- |
| –
| Check wiring and plug connections to the coolant shut-off valve -N279- according to the current flow diagram |
|
| | |
Open circuit/short-circuit to earth | t
| Open circuit or short-circuit to earth on wiring or plug connections to coolant shut-off valve -N279- |
| –
| Check wiring and plug connections to the coolant shut-off valve -N279- according to the current flow diagram |
|
| | |
01271 Temp. flap control motor -V68 | Short circuit to positive | t
| Short-circuit to positive on wiring or plug connections to the control motor for temperature flap -V68- |
| –
| Check wiring and plug connections to the control motor for temperature flap -V68- according to the current flow diagram. |
|
t
| control motor for temperature flap -V68- defective |
| –
| Analysing measured value block 005 → Chapter |
–
| Performing final control diagnosis (function 03) → Chapter |
|
Short circuit to earth | t
| Short-circuit to earth on wiring or plug connections to the control motor for temperature flap -V68- |
| –
| Check wiring and plug connections to the control motor for temperature flap -V68- according to the current flow diagram. |
|
t
| control motor for temperature flap -V68- defective |
| –
| Analysing measured value block 005 → Chapter |
–
| Performing final control diagnosis (function 03) → Chapter |
|
Blocked or dead
adaption limit exceeded
adaption limit not reached | t
| Open circuit or short-circuit to earth or positive on wiring to the control motor for temperature flap -V68- |
| –
| Check wiring and plug connections to the control motor for temperature flap -V68- according to the current flow diagram. |
|
| –
| Check smooth operation of temperature flap |
|
t
| control motor for temperature flap -V68- defective |
| –
| Analysing measured value block 005 → Chapter |
–
| Performing final control diagnosis (function 03) → Chapter |
|
Adaption not performed | t
| Basic setting (function 04) was not or incorrectly performed. |
| –
| Perform initiate basic setting (function 04) → Chapter |
|
01296 Vent temperature sender Centre -G191 | Short circuit to earth | t
| Short-circuit to earth on wiring or plug connections to the vent temperature sender, centre -G191- |
| –
| Check wiring and plug connections to the -G191- according to the current flow diagram. |
|
| –
| Analysing measured value block 003 → Chapter |
|
Open circuit/short circuit to positive | t
| Open circuit or short-circuit to positive on wiring or plug connections to the vent temperature sender, centre -G191- |
| –
| Check wiring and plug connections to the -G191- according to the current flow diagram. |
|
| –
| Analysing measured value block 003 → Chapter |
|
01297 Vent temperature sender Footwell -G192 | Short circuit to earth | t
| Short-circuit to earth on wiring or plug connections to the vent temperature sender, footwell -G192- |
| –
| Check wiring and plug connections to the -G192- according to the current flow diagram. |
|
| –
| Analysing measured value block 003 → Chapter |
|
Open circuit/short circuit to positive | t
| Open circuit or short-circuit to positive terminal on wiring or plug connections to the vent temperature sender, footwell -G192- |
| –
| Check wiring and plug connections to the -G192- according to the current flow diagram. |
|
| –
| Analysing measured value block 003 → Chapter |
|
01299 Data bus diagnostic interface Gateway -J533-3) | no communication | t
| Fault in databus wiring |
| –
| Check the data BUS wiring according to the current flow diagram. |
|
t
| Wrong or faulty vehicle voltage control unit -J519- |
| |
please read out fault memory 4) | | |
01314 Engine control unit | please read out fault memory 4) | t
| Fault entry in 4AV control unit |
| |
01317 Control unit with display in dash panel insert -J285 | please read out fault memory 4) | t
| Fault entry in the control unit with display in dash panel insert -J285- |
| |
implausible signal | t
| Fault in databus wiring |
| –
| Check the data BUS wiring according to the current flow diagram. |
|
t
| Wrong or defective dash panel insert |
| |
01596 Fresh/re-circulating air flap control motor -V154 | Short circuit to positive | t
| Short-circuit to positive terminal or plug connections to the -V154- |
| –
| Check wiring and plug connections to the fresh/re-circulating air flap -V154- according to the current flow diagram. |
|
| –
| Analysing measured value block 004 → Chapter |
–
| Performing final control diagnosis (function 03) → Chapter |
|
Short circuit to earth | t
| Short-circuit to earth terminal or plug connections to the -V154- |
| –
| Check wiring and plug connections to the fresh/re-circulating air flap control motor -V154- according to the current flow diagram. |
|
| –
| Analysing measured value block 004 → Chapter |
–
| Performing final control diagnosis (function 03) → Chapter |
|
Blocked or dead
adaption limit exceeded
adaption limit not reached | t
| Open circuit or short-circuit to earth or positive on wiring or plug connections to the -V154- |
| –
| Check wiring and plug connections to the fresh/re-circulating air flap control motor -V154- according to the current flow diagram. |
|
t
| Fresh/re-circulating air flap jams |
| –
| Test smooth operation of fresh/re-circulating air flap |
|
| –
| Analysing measured value block 004 → Chapter |
–
| Performing final control diagnosis (function 03) → Chapter |
|
Adaption not performed | t
| Basic setting (function 04) was not or incorrectly performed. |
| –
| Perform initiate basic setting (function 04) → Chapter |
|
65535 Control unit defective | | t
| Air conditioning system control unit -J301- defective |
| –
| Replace the air conditioning system control unit -J301- → Chapter and perform initiate basic setting (function 04). |
|