| Reading measured value block 4 | → | Readout on display |
| 52 | 52 | 206 | 52 | |
| | | | | After performing basic setting (function 04) established value of the potentiometer -G143- (in the fresh/re-circulating air flap control motor - V154-) in re-circulating air operation t
| Specified value: 5 to 100 1) |
|
| | | | After performing basic setting (function 04) established value of the potentiometer -G143- (in the fresh/re-circulating air flap control motor -V154-) in fresh air operation t
| Specified value: 150 to 250 1) |
|
| | | Nominal feedback value of the potentiometer -G143- (in the fresh/re-circulating air flap control motor -V154-)t
| Specified value: 0 to 255 |
|
| | Actual feedback value of the potentiometer -G143- (in the fresh/re-circulating air flap control motor -V154-)t
| allowed deviation from nominal value ± 2 |
|
| |