| Connect the pneumatic hose -1- (pneumatic support) to tester for charge air system. |
Note If there is water in the inspection glass, drain water via the drain plug -6-. |
–
| Set the pressure to 0.05 MPa (0.5 bar) with the pressure control valve -2-. |
Caution The pressure must not be greater than 0.05 MPa (0.5 bar)! A too high pressure can damage the engine. |
|
–
| Open valve -4- and wait until the test circuit is filled up. If necessary readjust pressure to 0,05 MPa (0,5 bar). |
–
| Listen to, touch or use commercially available leak search spray or the ultrasonic measuring device e. g. -V.A.G 1842- to check the charge-air system for leak points. |
Note t
| Minor leaks are permissible on the suction side of the turbocharger, because the intake hoses are not designed for overpressure. |
t
| A small amount of air penetrates via the valves into the engine. For this reason no pressure test is possible. |
t
| In case of a leak point, observe the instructions for charge air system → Chapter during the installation. |
t
| Before removing the adapter, depressurize the test circuit by detaching the coupling from the adapter -1687/10-. |
|
|
|