| Insert injector to be tested in a measuring glass. |
–
| Activate the remote control -V.A.G 1348/3 A- for 30 seconds. |
–
| Put the measuring glass with the injected fuel in a safe place. |
–
| Perform the measurement in sequence on all the injection valves. While doing so, use additional measuring glasses. |
–
| After all the injection valves have been operated, place all the measuring glasses on a flat surface and compare the quantities of fuel injected. |
Note The injection rate must be the same for all injection valves. |
Specified value per injection valve: 85...99 ml |
If the measured value is outside the range of the nominal value: |
The installation of the fuel distributor with the injection valves is performed in the reverse order to the removal, while paying attention to the following: |
t
| Replace the O-rings on all the injectors and moisten lightly with clean engine oil. |
t
| Fit the fuel rail with the installed injection valves to the intake manifold and tighten screws uniformly to 10 Nm. |
t
| Disconnect the electrical cables installed for the test and re-insert fuse No. 61. |
|
|
|