skoda Workshop Repair Guides

Skoda Workshop Service and Repair Manuals

Self-diagnosis functions > < Self diagnosis for the xenon headlight with automatic regulation
Connecting vehicle system tester V.A.G 1552
Connecting vehicle system tester V.A.G 1552
Special tools and workshop equipment required
t  Vehicle system tester -V.A.G 1552-
t  Diagnostic cable -V.A.G 1551/3, 3A, 3B oder 3C-
Test conditions
l  All fuses must be OK in compliance with the current flow diagram.
l  Battery voltage at least 11 V.
The diagnostic connection is located on the left next to the storage compartment on the driver's side.
–  Unclip cover and remove downward.
   
–  Connect vehicle system tester -V.A.G 1552- with appropriate cable.
Switch on ignition.
  S01-0087
Readout on display:
  Note
If there is nothing on the display → Operating instructions for the vehicle system tester.
–  Enter address word 55“Actuator diagnosis” and confirm the entry with Q.
 
Vehicle system test                 HELP
Enter address word XX
Readout on display:
t  6N0907503: Version number of the control unit
t  Headlight range regulation: System denomination
t  0004: Software version number
t  00010: Coding control unit
t  WSC 00000: Workshop code
 
6N0907503   Headlight range regulation   0004->
Coding 00010                   WSC 00000

Self-diagnosis functions > < Self diagnosis for the xenon headlight with automatic regulation